TECHNICAL
SPECIFICATIONS FOR HIGH PRESSURE COMPRESSORS
CTP
300/CTP-F 300/CTP-S 300
|
|
ADVANCED TECHNOLOGY HAS PERFECTED THESE ECONOMICAL , COMPACT, SAFE
, RELIABLE AND EASILY MAINTAINED UNITS.
A COMPLETE LINE OF ACCESSORIES IS AVAILABLE TO MEET YOUR REQUIREMENTS.
|
| medium |
|
breathing
air ACC. DIN 3188 / EN 12021 |
| intake
pressure |
bar
abs. |
1 -
1.2 |
| rated
overpressure |
bar
max. |
350 |
delivered
quantity measured acc.
bottle filling standard from 0 to 200 bar |
l /
min. |
300 |
| m³
/ h |
18 |
| speed |
r.p.m.
|
1850 |
| number
of stages |
|
3 |
| number
of cylinders |
|
3 |
cylinder
1st stage
cylinder 2nd stage
cylinder 3rd stage
|
ø
mm |
88 |
| 36 |
| 14 |
| piston
travel |
mm |
40 |
intermediate
overpressures
1st stage approx.
2nd stage approx. |
bar |
7 |
| 40-46 |
| final
pressure |
bar |
225-330 |
| rotating
direction |
|
counterclockwise |
| cooling |
|
air |
| lubrication |
|
splash
lubrication with oil whizzer pin |
| quantity
of lubricating oil |
l |
1,8 |
| oil
type |
|
synthetic
oil |
|
tolerated maximum ambient temperature |
°C |
+5
..... +45° C |
| tolerated
maximum inclination |
|
5° |
| condensate
drain |
|
every
10-15 min., manually |
drive
motor
three-phase squirrel cage motor (E3)
Honda motor GX 340 (P)
Hatz Diesel Motor 1 D81 (DHA)
|
7,5 kW
8,0 kW
10,5 kW |
400/660 V, 50/60 Hz, 2900 r.p.m., design B3, type of protection IP
55
manual starter
manual starter |
electrical
control
operating voltage
control voltage |
V/Hz |
400 V, 50/60 Hz |
| 230
V, 50/60 Hz |
pressure
switch adjustment
cut-out pressure, max./min.
cut-in pressure, max./min. |
bar |
330/150 |
| 295/135
|
|
weight
netto
CTP 300 E3 / P / DHA
CTP-F
300 E3 / P / DHA
CTP-S 300
|
kg |
108 / 121 / 159
185 / 190 / 169
265 |
dimension
L x W x H
CTP 300 E3 / P / DHA
CTP-F
300 E3 / P / DHA
CTP-S 300 |
cm |
87x42x73 / 107x44x70 / 107x44x70
90x60x87 / 107x55x76 / 107x55x76
105x70x125 |