print specification
TECHNICAL SPECIFICATIONS FOR HIGH PRESSURE BOOSTER COMPRESSOR
CTP-B 200
FUNCTION AND WORKING METHOD OF A FAST FILLING STATION WITH INTEGRATED BOOSTER:
IN AUTOMATED COMPRESSOR OPERATION DURING IDLE PERIODS, I.E. DURING THE NIGHT, THE STORAGE SYSTEMS ARE FILLED. DURING DAY TIME, WHEN A LARGE NUMBER OF SMALL TANKS HAVE TO BE FILLING WITHIN A SHORT TIME, COMPRESSORS ARE SWITCHED OVER TO BOOSTER OPERATION.
THIS IS EFFECTED BY SIMPLY OPERATING A HIGH PRESSURE VALVE.
THE HIGH PRESSURE STAGE OF THE MULTISTAGE HIGH PRESSURE COMPRESSOR IS NOW DIRECTLY CONNECTED TO THE STORAGE SYSTEM AND THE PRE-COMPRESSED AIR FROM THE STORAGE SYSTEM FLOWS INTO THE SMALL TANKS. AS SOON AS THERE IS A PRESSURE BALANCE IN THE SYSTEM, THE HIGH PRESSURE VALVE SWITCHES OVER TO BOOSTER OPERATION AND THE LAST COMPRESSOR STAGE COMPRESSES UP TO REQUESTED FINAL PRESSURE.
OPERATION OF THE SWITCH-OVER VALVE WILL BE CARRIED OUT BY ELECTRO-PNEUMATIC REMOTE CONTROL.
medium   breathing air ACC. DIN 3188 / EN 12021
intake pressure bar abs. 1 - 1.2
rated overpressure bar max. 350
delivered quantity measured at filling standard
from 0 to 200 bar depending of storage pressure
l / min. 200 - 1200
m³ / h 12,6 - 54
speed

r.p.m.

1300
number of stages   3
number of cylinders   3
cylinder 1st stage
cylinder 2nd stage
cylinder 3rd stage
ø mm 88
36
14
piston travel mm 40
intermediate overpressures
1st stage approx.
2nd stage approx.

bar

7
40 - 46
filling pressure ( fin.safety valve) bar 225-330
rotating direction   counterclockwise
cooling   air
lubrication   splash lubrication with oil whizzer pin
quantity of lubricating oil l 1,8
oil type   see chapter 2 , Lubrication
tolerated maximum ambient temperature  °C +5 to +45
tolerated maximum inclination  
condensate drain   every 10-15 min., manually
drive motor
three-phase squirrel cage motor (E3)
HONDA-motor GX 270 (P)
HATZ-diesel engine 1 B 30 (DHA)

4,0 kW

400/660 V, 50/60 Hz, 2900 r.p.m., design B3, type of protection IP 55
6,6 kW manual starter
4,6 kW manual starter
special voltage on request
electrical control
operating voltage
control voltage
V/Hz
400 V, 50/60 Hz
230 V, 50/60 Hz
pressure switch adjustment
cut-out pressure, max./min.
cut-in pressure, max./min.
bar
330/150
295/135

weight netto
CTP-B 200 E3
/ P / DHA

kg
165
dimension L x W x H
CTP-B 200 E3 / P / DHA
cm
90 x 60 x 87

home