TECHNICAL
SPECIFICATIONS FOR HIGH PRESSURE BOOSTER COMPRESSOR
CTP-B
300
|
|
FUNCTION
AND WORKING METHOD OF A FAST FILLING STATION WITH INTEGRATED BOOSTER:
IN AUTOMATED COMPRESSOR OPERATION DURING IDLE PERIODS, I.E.
DURING THE NIGHT, THE STORAGE SYSTEMS ARE FILLED. DURING DAY TIME,
WHEN A LARGE NUMBER OF SMALL TANKS HAVE TO BE FILLING WITHIN A SHORT
TIME, COMPRESSORS ARE SWITCHED OVER TO BOOSTER OPERATION.
THIS IS EFFECTED BY SIMPLY OPERATING A HIGH PRESSURE VALVE.
THE HIGH PRESSURE STAGE OF THE MULTISTAGE HIGH PRESSURE COMPRESSOR
IS NOW DIRECTLY CONNECTED TO THE STORAGE SYSTEM AND THE PRE-COMPRESSED
AIR FROM THE STORAGE SYSTEM FLOWS INTO THE SMALL TANKS. AS SOON
AS THERE IS A PRESSURE BALANCE IN THE SYSTEM, THE HIGH PRESSURE
VALVE SWITCHES OVER TO BOOSTER OPERATION AND THE LAST COMPRESSOR
STAGE COMPRESSES UP TO REQUESTED FINAL PRESSURE.
OPERATION OF THE SWITCH-OVER VALVE WILL BE CARRIED OUT BY ELECTRO-PNEUMATIC
REMOTE CONTROL.
|
| medium |
|
breathing
air ACC. DIN 3188 / EN 12021 |
| intake
pressure |
bar
abs. |
1 -
1.2 |
| rated
overpressure |
bar
max. |
350 |
delivered
quantity measured at filling standard
from 0 to 200 bardepending of storage pressure |
l /
min. |
300
- 1200 |
| m³
/ h |
15,6
- 54 |
| speed |
r.p.m.
|
1850 |
| number
of stages |
|
3 |
| number
of cylinders |
|
3 |
cylinder
1st stage
cylinder 2nd stage
cylinder 3rd stage
|
ø
mm |
88 |
| 36 |
| 14 |
| piston
travel |
mm |
40 |
intermediate
overpressures
1st stage approx.
2nd stage approx. |
bar |
7 |
| 40 -
46 |
| filling
pressure ( fin.safety valve) |
bar |
225-330 |
| rotating
direction |
|
counterclockwise |
| cooling |
|
air |
| lubrication |
|
splash
lubrication with oil whizzer pin |
| quantity
of lubricating oil |
l |
1,8 |
| oil
type |
|
see
chapter 2 , Lubrication |
|
tolerated maximum ambient temperature |
°C |
+5
to +45 |
| tolerated
maximum inclination |
|
5° |
| condensate
drain |
|
every
10-15 min., manually |
drive
motor
three-phase squirrel cage motor (E3)
Honda Petrol 4-stroke motor GX 340 (P)
Hatz Diesel motor 1 D81 (DHA) |
7,5 kW |
400/660 V, 50/60 Hz, 2900 r.p.m., design B3, type of protection IP
55 |
| 8,0
kW |
manual
start model |
| 10,5
kW |
manual
start model |
electrical
control
operating voltage
control voltage |
V/Hz |
400 V, 50/60 Hz |
| 230
V, 50/60 Hz |
pressure
switch adjustment
cut-out pressure, max./min.
cut-in pressure, max./min. |
bar |
330/150 |
| 295/135
|
|
weight
netto
CTP-B 300 E3 / P / DHA
|
kg |
176 |
dimension
L x W x H
CTP-B 300 E3 / P / DHA |
cm |
90 x 60 x 87 |